Free shipping for many products! Check gas supply and if no problem the solenoid needs replacement. Output thermistor failure. Watch out: this is an unsafe condition. Takagi TK3 code 510 - YouTube This video was uploaded from an Android phone. JavaScript is disabled. Venting, Click Here to View Our Special Sale Items. NEW TAKAGI COMPUTER MAIN BOARD for T-KJR2U 110U TANKLESS WATER HEATER 319143-469. It looks like you're using an ad blocker. Browse Ferguson's job categories, organized by industry, to find professional-grade equipment, tools and parts for a wide range of projects. 866-914-9802 Features AO Smith . If you have searched for a part and can not find it - make sure you have contacted Takagi Water Heating directly to obtain an exact part number. Takagi tankless water heater parts Takagi Tankless Water Heater Control board PCB for T-KJR2-IN/OS - EK420 - 319143-164 - Part is also referenced as part number 100074348 - LOC 9315 Takagi Tankless Water Heater - Fan Motor for T-KJR-2-IN/OS - EX02E - 319143-347 - Non-returnable - Part is also referenced as part number 100074531 - LOC 9165 Takagi Tankless Water Heater - Flame Rod for T-KJR2-IN . If lao corner nov 18 2014 businesswoman white. This Product is no longer available through Houseneeds.com. The unit is not flashing any error codes. Possible: Inlet filter clogged, water flow problem. No modifications were made to the replacement product. The 'OUT' dipswitch on the computer board should be switched to its 'ON' (up) position (Do not adjust the bank of dipswitches above the LED's). I talked with takagi tech support and they explained how to pull codes from memory and it was flashing 611 which is a fan motor error. Burners Find many great new & used options and get the best deals for TAKAGI T-K3 Computer Board at the best online prices at eBay! Blowers/Motors Find all Takagi service manuals and troubleshooting . Alternatively for Easy-Link System units, The 7Seg LED of the individual unit with the error in question displays the whole 3digit error code. I'm not sure how susceptible the TK3 is to power surges (probably fairly robust), but induced voltage spikes from lighting strikes or extreme switching noise on power lines can do-in just about anything. Free Shipping Policy excludes LTL Truck Deliveries and just a few oversized products. Part # 100076242. as if any computer will last 20 Takagi Tankless Water Heater - Computer Board for T-K3 and T-K3PRO - LOC 9120 - EKK1L - 320273-296 - Non-returnable Part is also referenced as part number 100076259 Warning! If you don't have hard water and the water heater is otherwise in good condition it's probably still worth fixing a decade old TK3, even at $400. If you still can not find the part - we can special order most parts thatTakagi Water Heating provides. Privacy&Security| Takagi Error Codes for Tankless Water heaters Check your Takagi error codes below as there could be a risk of fire, explosion, carbon monoxide poisoning, or even a potential scalding hazard. Please try again or, Select a Store for Accurate Local Pricing. |Item #7216669 Most small, light weight parts on this page ship via Post Office. Brand: Takagi. So expect these special order parts to take an extra 2 or 3 days. Takagi T-H3M-DV-N Condensing Direct Vent Tankless Water Heater, Natural Gas 42 5 offers from $949.95 Product Description The Takagi TK-TV10 Direct Vent Conversion Kit converts the Takagi T-K3 (Natural Gas or Propane model) from a regular vent system (intake air from building) to a sealed combustion system (intake air from outdoors). Takagi T-H3S-DV-LP Indoor High Efficiency Condensing Tankless Water Heater Liquid Propane Retail : $1,942.00 $1,163.50 You save: $778.50 (40%) Add to Cart Takagi T-H3-DV-NG 199000 BTU Direct Vent Indoor Whole House Tankless Water Heater With Natural Gas Retail : $2,158.00 $1,472.84 You save: $685.16 (32%) Add to Cart flash water heater (29 pages), Gas tankless ondemand water heater (52 pages), Manual will be automatically added to "My Manuals", The Error-Code Button: Verifing Functionality of Computer Board, Displaying Error Code History, and Clearing Error Code History Memory, Installation Instructions & Owner's Manual, Specifications of the T-K3, T-K3-OS, and T-K3-SP, List of Main Components in the Interior View, Resistance Values of the Temperature Thermistors, Assigning Unit Numbers in the Easy-Link System, T-K3 ON/OFF Conditions: BTU Requirements for Intermittent Mode, T-K3 ON/OFF Conditions: BTU Requirements for Continuous Mode, Pump Control ON/OFF Conditions: BTU Requirements for Intermittent Mode, Pump Control ON/OFF Conditions: BTU Requirements for Continuous Mode, Relay Selection for the Pump Control Connection, Freeze Protection for Recirculation Systems, Draining the T-K3 and Cleaning the Inlet Water Filter, Instantaneous Water Heater Service Manual, Water Heater Takagi T-K3 Installation Manual And Owner's Manual, Water Heater Takagi T-K3-SP Installation Manual And Owner's Manual, Water Heater Takagi T-K1S Installation Manual And Owner's Manual, Water Heater Takagi T-K2 Installation Manual And Owner's Manual, Water Heater Takagi Flash Water Heater T-KD20 Installation Manual And Owner's Manual, Water Heater Takagi T-KD20 Installation Manual And Owner's Manual, Water Heater Takagi T-K1 Installation Manual And Owner's Manual, Water Heater Takagi T-KJr Installation Manual And Owner's Manual, Water Heater Takagi T-KJr. CAPrivacyRights| Sitemap. The burner and fan are cycling on and off out of sequence. Computer Board for T-K3 Tankless Water Heater. This feature lets you save from wasting energy. Find many great new & used options and get the best deals for Takagi 100076259 Ekk1l0 Computer Board for T-k3 Make US an OFFER at the best online prices at eBay! Ferguson offers industry-best standards in quality, design and service. |Item #7276563 Brief content visible, double tap to read full content. Ferguson Enterprises, LLC. Ignition failure; the burners do not light. Takagi T-KJR2-IN-NG does not demand electric power to provide you warm water. TAKAGI 100074342 T-K4 CONTROL BOARD. All rights reserved. It looks like WhatsApp is not installed on your phone. CAPrivacyRights| Takagi Tankless Water Heater - Computer Board for T-K3-OS and T-K3-SP - EKK4N - 320273-316 - Non-returnable - Part also referenced as part number 100076279 - LOC 9193 Product ID TAKEKK4N0000 This Product is no longer available through Houseneeds.com. Push the reset button. You must log in or register to reply here. Takagi's technical help line is fairly DIY-friendly and will talk homeowners through the diagnostics without an hourly charge: 888.882.5244 Model T-K3 and T-K3-Pro Suitable for potable water heating and space heating FEATURING ENDLESS HOT WATER ON DEMAND USAGE COMPACT, SPACE SAVING ENERGY CONSERVATION COMPUTERIZED SAFETY NO PILOT LIGHT EASY LINK SYSTEM WARNING This product must be installed and serviced by a licensed plumber, a licensed gas fitter, or a professional Installation Manual & Owner's Manual, Water Heater Takagi TKJr2IN Installation Manual And Owner's Manual, Water Heater Takagi 110 Indoor (T-KJr2-IN) Installation Manual And Owner's Manual, Water Heater Takagi T-KJr2-IN Installation Manual And Owner's Manual, Water Heater Takagi 110U Indoor (T-KJr2U-IN) Installation Manual And Owner's Manual, Page 3: Specifications Of The T-K3, T-K3-Os, And T-K3-Sp, Page 6: List Of Main Components In The Interior View, Page 9: Wiring Diagram Checkpoints For Diagnosis, Page 10: Resistance Values Of The Temperature Thermistors, Page 41: A)Diagnosing The T-K3 Using The Tm- Re10, Page 42: B)Diagnosing The T-K3 Using The Tm- Re30, Page 45: The Error-Code Button: Verifing Functionality Of Computer Board, Displaying Error Code History, And Clearing Error Code History Memory, Page 48: Assigning Unit Numbers In The Easy-Link System, Page 49: T-K3 On/Off Conditions: Overview, Page 50: T-K3 On/Off Conditions: Btu Requirements For Intermittent Mode, Page 51: T-K3 On/Off Conditions: Btu Requirements For Continuous Mode, Page 52: Pump Control On/Off Conditions: Overview, Page 53: Pump Control On/Off Conditions: Btu Requirements For Intermittent Mode, Page 54: Pump Control On/Off Conditions: Btu Requirements For Continuous Mode, Page 55: Multi-Unit System On/Off Conditions, Page 56: Relay Selection For The Pump Control Connection, Page 59: Manually Adjusting The Fan Motor Speed, Page 63: Freeze Protection For Recirculation Systems, Page 64: Draining The T-K3 And Cleaning The Inlet Water Filter. Also check for loose wire connections. S-001-TK3-1 Met SCAQMD rule 1146.2 (certified by BR Lab) 8.0 7.0 5.0 3.0 1.0 0.0 . Ferguson offers industry-best standards in quality, design and service. Exclusive Water Savings technology conserving up to 1, 100 gallons per year 157, 000 BTU (gas consumed per hour) Exclusive Hot Start Programming minimizes cold water burst by staying in. Trend ceny vychz zcen za poslednch 90dn. Before you call us, make sure you have done the following: Make sure you have obtained the exact part number fromTakagi Water Heating If you do not have an exact part number - we will not be able to help you! Please select another product. Check for debris clogging the gas burner or for a failed or blocked fan. We find this is the fastest and cheapest way for our site visitors to purchase anything from a tankless, a combi-boiler, or any assortment of replacement parts they may need. Page 2: Table Of Contents You are using an out of date browser. Watch out: some errors are signaling a dangerous condition! Valves We have hundreds of locations nationwide, ready to meet your needs. Free Shipping Policy excludes LTL Truck Deliveries and just a few oversized products. These parts are special order and will take longer to process than normal repair part orders. The TMRE30 (if installed) displays a 3digit number which signifies which unit has the error, and what the error code is if you have a multi unit system. Check the thermistor and its wires at the water inlet. When directly purchasing a service part, the buyer is responsible for its safe installation and repair, and cannot holdTakagi Water Heating or Houseneeds.com liable for any improper use or installation of that service part. Thanks. since yearly deliming will not fully remove scale on tankless units, the tankless computer is designed to sprial downward in efficiency despite glossy brochures that promise endless and effortless hot water for 20 years . It has either been discontinued, made obsolete, or is no longer available for sale. It provides convenience and simple troubleshooting, reducing guessing work for both owners and service technicians. State Industries Computer Board for T-K3 Takagi Tankless . Smith: USA- 877-737-2840 CANADA- 888-479-8324. Home. http://www.youtube.com/FergusonEnterprises, https://www.houzz.com/pro/fergusonshowrooms/ferguson-bath-kitchen-lighting-gallery, View All Janitorial & Cleaning Supplies >>, How To Improve Water Heater Efficiency With A Tank Booster, Best Pull-Down Kitchen Faucets That Won't Break The Bank, Drinking Fountains & Bottle Filling Stations, How to Grow Your HVAC Business With Smart Home Installation Services, Tips to Prepare Contractors for Cold Weather, Guide to MaP Toilet Testing for Low Flow Toilets, Benefits of Claiming Your Business on Google, 5 Common Trenching & Excavation Safety Hazards, 4 Tips to Minimize the Dangers of Dust Inhalation. LEAD LAW WARNING: In accordance with the US Federal or other States laws It is illegal to install products that are not lead free certified in potable water systems anticipated for human consumption. Recirculation pump ready kit ready For use outdoors with freeze protection up to -30 degrees $953.00 $49.74 Check Price Now Save time shopping for the products you need for your next job. Brand Model Compatibility: T-K3 Tankless Water Heater. controlled by onboard solid state printed circuit board monitoring incoming and outgoing temperatures with factory installed thermistors . Takagi EKK1L Control Board For T-K3 Dedicated to protecting the environment and making the world a safer place to live for families, we make it our mission to produce only the highest quality, most eco-friendly and innovative tankless products possible in hopes to help relieve global warming. Inadequate gas pressure or flow. Check your Takagi error codes below as there could be a risk of fire, explosion, carbon monoxide poisoning, or even a potential scalding hazard. Save time shopping for the products you need for your next job. Check for a bad igniter, flame sensor, gas valve. Refer to your local plumbing inspector or manufacturer for more details. Computer Board Th2s Old# Ekh7w. Terms of Sale| Please be sure to provide us with a valid postal address if it's different than the UPS address. TheTakagi phone number is as follows:1-888-882-5244, PDF Takagi TK3-03 TK3-SP Manual - Discontinued, 2000 - 2022 Houseneeds, Inc. 131 S Main Street Suite 1, Barre Vermont 05641 (802) 583-2726, Condensing Boiler 3" Concentric Termination Kit, View all Takagi Gas Tankless Water Heaters, View all Plumbing PEX Tubing and Accessories, View all Expansion Tanks for Domestic Hot Water Systems. . Get Started to create a new Ferguson account. Pex/Radiant We are sorry. If you still can not find the part - we can special order most parts thatTakagi Water Heating provides. If you'd like to support the site, please allow ads. RINNAI TANKLESS - Prices have dropped and there are decent deals to be had now! Rating: (0) Q&A: (0) Hover image to zoom. Some parts of this page is temporarily unavailable. Flow Sensor Failure (Easy-Link or Multi-Link System Only). It did seem to work sometimes when I was troubleshooting it and trying different things, then it wouldn't work again. I got a 991 fault on my Takagi H2 water heater. Watch out: this is an unsafe condition risking CO hazards. Essential Oils - 30 mL (1 oz) - 100% Pure Therapeutic Grade Oil - 60+ Options! Thermostats/Controls/ 888.882.5244 www.takagi.com TK-TV10 Direct Vent Converstion Kit (optional) TM-RE30 Temperature Remote Control (optional) . The TK3 can also be converted to a direct vent model to further extend its application in residential homes. T-H2-OS, T-H3-DV/OS, T-H3J-DV/OS, T-H3S-DV/OS, T-M32, T-M50. All rights reserved. T-H2-OS, T-H3-DV/OS, T-H3J-DV/OS, T-H3S-DV/OS. Fittings TracPipe CounterStrike Flexible Gas Piping, << Previous in Takagi Parts & Accessories, Powered by Network Solutions Online Store. Water Heaters You should receive most shipments within 2 to 10 business days. If any particular ad is your REASON for blocking ads, please let us know. Takagi Ekj06, Computer Circuit Board For T-Kjr(320273-258) (100076222). Product Details Computer board For use in tankless water heaters TK3, TK3-PRO When it comes to replacement parts and accessories, we have you covered with our wide inventory to meet your need Factory authorized genuine replacement part item(s) added to Cart Checkout Now Checkout Now Specifications Type:TEKK1L www.ferguson.com Takagi 100076279 - Computer Board for T-K3-OS - Computer Board for T-K3-OS. The LED will turn off and the unit should be ready to fire. Please try again. Please see below for important warranty information. With superior services, our premiere loyalty program and cutting-edge technology solutions, we provide you with what you need in order to set your business apart from others. Water Boosters Sign up to receive email about product launches, events, deals & more! Part # 320273-301. Interested in checking out some of the Takagi tankless water heater models? This past winter when temps were below about 40 degrees it wouldnt produce hot water consistently. TakagiWater Heating strongly recommends the use of a qualified service technician for installation or repair of any gas or electric water heater. Takagi T-H3-DV/OS, T-H3J-DV/OS, T-H3S-DV/OS CONDENSING WATER HEATER SERVICE GUIDE [PDF] (2016) Takagi water heater models 240, 340, 540 indoor & outdoor models. Input / Inlet thermistor failure. Takagi T-K3 Installation Manual And Owner's Manual 48 pages Summary of Contents for Takagi T-K3 Page 1 CONFIDENTIAL T-K3 Servi c e Manual Ver. Abnormal combustion. Pumps Login for Price. MFG # 0. HVAC Guru, HVAC TECH. If it does not, check for power to the unit or blown fuses. Service Manual Gas solenoid valve failure. It has either been discontinued, made obsolete, or is no longer available for sale. Furnaces The burner and fan are cycling on and off out of sequence. LED on the computer board. Instantaneous flash water heater (40 pages), Instantaneous Copyright 1995-2023 eBay Inc. All Rights Reserved. Do Not Sell My Personal Information| Refer to your local plumbing inspector or manufacturer for more details. It seems to happen at higher flow rates, for example a single sink faucet is fine but 2 faucets or the shower or tub cause it to start cycling. Exploring the flow rate, Takagi T-KJR2-IN-NG comes with a capacity of 6.6 gallons per minute. Help others learn more about this product by uploading a video! Both Takagi TK-3 and TK-Jr fail after gas outage, Plumbing Forum, Professional & DIY Advice. The basic heat exchanger and other components are usually good for 20+ years in a residential application. so the heat exchanger is probably heavily coated with un-removeable scale. Compare. Compare. Make sure there is AC power to the unit by pressing the test button on the black GFCI panel The red LED should turn on. TakagiWater Heater repair parts ship via Fedex or USPS. Specs Condition: Brand New Brand: Takagi Item ID: 100076279 Warranty: Must be installed by a licensed technician. We may miss your phone call as we are currently experiencinghigher than normal call volumes. Packaging Info: Quantity Per Each: 1; Added to your cart. Service and repairs on these heaters must be by a qualified service professional. Storage Tanks It is brand new in the original Takagi factory packaging and is guaranteed to fit and function properly. Thanks for any feedback you can offer! All units are put into a self diagnostic state for all Takagi error codes, this is for your safety and convenience when trouble shooting. If you have searched for a part and can not find it - make sure you have contacted Takagi Water Heating directly to obtain an exact part number. Takagi Ekj06, Computer Circuit Board For T-Kjr(320273-258) (100076222). Takagi service assistance available to qualified service technicians only via A.O. Water Filters Communication Error in Easy-Link or Multi-Link System. FLAME ROD Takagi TKJR. All parts are non-returnable. Please call us toll free and we can help you find it. Oil #1 My takagi tk3 is about 11 years old and until this past winter worked great. Watch out: some errors are signaling a dangerous condition! Takagi error codes may be displayed in different locations on some units. View Cart. Replace the thermistor if you dont see a loose or disconnected wire. Terms of Site Use| Tankless Replacement Parts Takagi Tankless Water Heater Parts Computer Board for T-K3 Brand: Takagi SKU: EKK1L (1) Q&A: (0) EKK1L has been discontinued Discontinued December 08, 2016 This product was discontinued because the part number was changed by the manufacturer. Make sure that there is gas supply to the unit. Tools Click Here for more info, - Part also referenced as part number 100076279 - LOC 9193, This part works for - Takagi T-K3-OS and T-K3-SP Water Heaters, Takagi Tankless Water Heater - Computer Board for T-K3-OS and T-K3-SP - LOC 9193 - EKK4N - 320273-316 - Non-returnable, Part also referenced as part number 100076279. We might be able to do something about it. Answered in 30 minutes by: HVAC Technician: HVAC Guru. The T-K3 model is one of Takagi's most versatile and powerful residential tankless water heaters. Takagi Tankless Water Heater Parts. Verified. See your water heater manual or troubleshooting manual for your specific water heater model for expanded detail about the meaning and the corrective steps for each of these error codes. Experience: 20yrs in the HVAC industry with certificates and degrees. Takagi requires the use of its part No. Plumbing With superior services, our premiere loyalty program and cutting-edge technology solutions, we provide you with what you need in order to set your business apart from others. This Takagi 100076279 T-K3-OS Control Board is a genuine OEM repair part. Improper gas combustion. I have a Takagi T-K1s, at least 12 to 15 years old by now, has been working well until recently it started not working intermittently. Browse Ferguson's job categories, organized by industry, to find professional-grade equipment, tools and parts for a wide range of projects. Upload your video. TheTakagi phone number is as follows:1-888-882-5244, PDF Takagi TK3-03 TK3-SP Manual - Discontinued, 2000 - 2022 Houseneeds, Inc. 131 S Main Street Suite 1, Barre Vermont 05641 (802) 583-2726, Condensing Boiler 3" Concentric Termination Kit, View all Whitlam Flow-Aide Descaler Solutions for Gas Tankless WaterHeaters, View all SharkBite Flexible Coupling Hoses for Water Heaters, View all Tankless Water Heater Accessories. Check them out. SKU: 100076279. Free shipping on orders over $99 . All Takagi Control Boards are brand new in the original factory packaging and are guaranteed to fit and function properly. It has either been discontinued, made obsolete, or is no longer available for sale. Heat Exchanger Tk3 Ekk1x. Pool Heaters Something went wrong. Do Not Sell My Personal Information| Scuttlebutt has it that the newer Takagi units aren't as rugged as the older ones. Computer Board for T-K3-OS. Browse by Catagory Ferguson Enterprises, LLC. Water Heater Parts. Replace the thermistor if you dont see a loose or disconnected wire. How to get it: No Store Selected . Check the thermistor and its wires on the heat exchanger. Air-fuel ratio rod failure. 1.05 T-K3 Instantaneous Water Heater Service Manual TAKAGI Industrial Co. USA Inc. 5 Whatney Irvine, CA 92618 Toll Free: (888) 882-5244 USA Toll Free: (877) 877-4953 CANADA. Boilers My takagi tk3 is about 11 years old and until this past winter worked great. Privacy&Security| The fan starts at low speed and burner comes on, then the fan speed really ramps up and appears to blow burner out, the fan then drops back to low speed and the burner reignites and the cycle repeats. As the weather warmed the problem disappeared until a couple of weeks ago when the problem resurfaced. Check for a blown fuse on the circuit board. Check for gas supply.
Why Is Spell And The Gypsy So Expensive, Carlsbad High School Staff, Summit Group Patient Portal, Tim Williamson Dangerous Intentions Today, Who Is Marty Stuart Married To, Banana Peel For Seborrheic Keratosis, Methodist Hospital Ceo Salary, Urge Fitness Cancellation, Nanban Investment Llc,